![Dentsply Sirona Sim Multi Bench Operating Instructions Manual Download Page 35](http://html1.mh-extra.com/html/dentsply-sirona/sim-multi-bench/sim-multi-bench_operating-instructions-manual_2483697035.webp)
Dentsply Sirona
Operating Instructions Simulation Unit Sim Multi Bench
4 Operation
4.3 Foot control
66 82 384 D3684
D3684.201.01.02.02 07.2019
35
4.3.2
C+ electronic foot control
The C+ electronic foot control can be set as a speed foot control or
direct starter for electric motors and the scaler. The compressed air for
the turbines is not adjustable.
Depending on whether the instruments are in their holders or an
instrument has been removed, the control elements of the C+ electronic
foot control have different functions. If an instrument is removed, the
last speed or intensity set will be shown on the SIM display of the
dentist element.
Foot pedal
S
0
ü
All instruments are in their holders.
➢ Press the foot pedal.
Ä
The SIM display of the dentist element switches to the standard
operating context (initial situation).
ü
An instrument is removed.
➢ Step on the foot pedal.
Ä
The instrument is activated. The motor or scaler is activated at
the set speed or intensity (direct starter).
Left button
S
0
S
ü
An instrument is removed.
➢ Press the left button.
Ä
Spray is switched on or off.
Right button
S
0
0
ü
An instrument is removed.
➢ Press the right button.
Ä
The chip blower remains switched on as long as the button is
pressed.
4-way switch plate
S
0
ü
The electric motor or the scaler is removed.
➢ Slide the 4-way foot switch plate up or down.
Ä
Up: The speed or intensity is increased.
Down: The speed or intensity is reduced.