A X - 3 S e r i e s O p e r a t i o n M a n u a l
7 - 1 0 0
_7
7.7.7.2 DIO Setting
The section describes setting funcitons including interrupt, filter and polarity of IOs in DIO device.
Double-click on “DIO” to enter the configuration page.
Configuration
Function
Description
External Interrupt
Setting
Default value
Activate external interrupt
When
external interrupt is activated, set input signals as rising edge.
When
external interrupt is activated, set input signals as falling edge.
When external interrupt is activated, set input signals as rising and
falling edge.
Port
Port number
Filter
Set filter time (
us), setting range is from 0 to 100000000. The
default is 100us.
Polarity
Set input polarity.
The default is
contact A .
Set input polarity,
The default is
contact B.