C h a p t e r 7 M o t i o n C o n t r o l B a s i c S e t t i n g s & O p e r a t i o n
7 - 7 9
7_
When position offset or scaling is not in default value, the following diagrams show the effects of the
corresponding relationship between master and slave actual positions during CAM execution:
For master and slave offset as 0, the effects from scaling of master and slave for actual CAM execution
Situations:
Situation 1: When scaling ratio for master and slave is 1, offset is 0, the actual CAM mechanism is the same as
pre-planned.
Situation 2: When master scaling ratio is 1, slave scaling ratio is 2 and offset for both axes is 0, the slave position
that corresponds to the master position is twice the amount of pre-planned measurement.
Situation 3: When master scaling ratio is 1, slave scaling ratio is 0.5 and offset for both axes is 0, the slave position
that corresponds to the master position is half the amount of pre-planned measurement.
Situation 4: When master scaling ratio is 2, slave scaling ratio is 1 and offset for both axes is 0, the master position
that corresponds to the slave position is twice the amount of pre-planned measurement. From CAM
phase perspective, the Master CAM is twice the amount of pre-planned measurement, meaning the
Master CAM changes from 360 to 180, while Slave CAM phase remains the same.
Summary of Contents for AX-3 Series
Page 17: ...AX 3 Series Operation Manual 1 10 _1 MEMO...
Page 54: ...AX 3 Series Operation Manual 3 22 _3 MEMO...
Page 98: ...AX 3 Series Operation Manual 4 44 _4 MEMO...
Page 118: ...AX 3 Series Operation Manual 6 8 _6 MEMO...
Page 310: ...AX 3 Series Operation Manual 8 18 8_ MEMO...
Page 355: ...Appendix A Troubleshooting A 5 _A...