![Delta AX-3 Series Operation Manual Download Page 247](http://html1.mh-extra.com/html/delta/ax-3-series/ax-3-series_operation-manual_2471629247.webp)
C h a p t e r 7 M o t i o n C o n t r o l B a s i c S e t t i n g s & O p e r a t i o n
7 - 1 2 9
7_
Software display
Can be configured via DIADesigner-AX software.
The positive and negative position are able to be resized on the configuration page:
Item
Data Type
Default Setting
Negative
LRAEL
0.0
Position
LRAEL
10000.0
7.7.8.3 Position Lag Setting
The command position as well as feedback position are located at zero while the axis is in motion. If there’s a
greart difference between command position and feedback position, an error will be reported.
The position lag reaction is set to be “Stay Enabled” as default.
Setting mode
Function
Deactivated
Not activated.
Disable drive
When position lag exceeds limit setting, axis will shift to servo off.
Do quickstop
When position lag exceeds limit setting, axis will shift to quick stop.
Stay enabled
When position lag exceeds limit setting, axis will remain as servo on.