![Delphin ProfiMessage Hardware Manual Download Page 221](http://html1.mh-extra.com/html/delphin/profimessage/profimessage_hardware-manual_2471098221.webp)
Profi
Message
Ethernet stand-
ards
10/100Base-T (half and full duplex), auto-negotiation
Protocols
TCP/IP, UDP, ICMP, HTTP, SMTP, NTP Modbus TCP Cli-
ent/Server
Connector
RJ45 (8-pin connector TP)
Galvanic isolation
1.5 kVeff
USB interface
Interface type
USB master
Transmission speed
USB 1.0 Full Speed (USB 1.1 compatible)
Power for external devices 5 V max. 500 mA (High Power)
Connector
USB connector type A
External bus (Ext. BUS)
Interface type
CAN 2.0B, ISO 11898-1, ISO 11898-2
Baud rate
max. 1 Mbaud
Connector
LP-3-pin terminal block (e.g. Wieland type 8113B/3VL)
Galvanic isolation 1 kV
COM1:
Interface
type
RS-485 interface
Baud rate
max. 12 Mbaud
Connector 9-pin D-SUB connector, pin assignment according to IEC 61158
Galvanic
isolation
1 kV (no isolation to CAN)
Features
Built-in PROFIBUS controller hardware 1) DP V1 slave, redundant
according to PNO document No. 2212 V1.2
1) The identification number for
Profi
Message
, as allocated by the German
PROFIBUS User Organization (PNO)
, is 0x09B8. Further information can be found
and
CAN (CAN bus)
221
Delphin Technology AG
Dezember 2015
Profi
Message Manual
Summary of Contents for ProfiMessage
Page 1: ......
Page 31: ...ProfiMessage 3 5 4 ADIT 31 Delphin Technology AG Dezember 2015 ProfiMessage Manual ...
Page 32: ...ProfiMessage 3 5 5 ADVT 3 5 6 AMDT 32 Delphin Technology AG Dezember 2015 ProfiMessage Manual ...
Page 33: ...ProfiMessage 3 5 7 DIOT 3 5 8 IOIT 33 Delphin Technology AG Dezember 2015 ProfiMessage Manual ...
Page 314: ...ProfiMessage 314 Delphin Technology AG Dezember 2015 ProfiMessage Manual ...
Page 322: ......