Profi
Message
The trigger (
blue
curve) starts the pulse generator (
red
curve) with a rising
edge. Then comes the reset (
purple
curve). Because the high level ("high")
remains, no further pulses are generated (
Reset
=
High level ).
Meanwhile, the
trigger channel switches to a low level ("Low"). However, because the reset chan-
nel remains at a high level as before, the trigger channel's edge has no effect. The
pulse generator does not re-start even when the reset channel reverts to a low
level as it is only re-started with an edge in the trigger channel. The pulse gen-
erator restarts only once the trigger channel has a (rising) edge.