About Your System
19
CAUTION:
Only trained service technicians are authorized to remove the system
cover and access any of the components inside the system. See your
Product
Information Guide
for complete information about safety precautions, working
inside the system, and protecting against electrostatic discharge.
NOTE:
If your system fails to boot, press the System ID button for at least five
seconds until an error code appears on the LCD. Record the code, then see "Getting
Help" on page 205.
Table 1-5.
LCD Status Messages
Code
Text
Causes
Corrective Actions
N/A
SYSTEM NAME
A 62-character string that
can be defined by the user in
the System Setup program.
The
SYSTEM NAME
displays under the following
conditions:
• The system is powered on.
• The power is off and
active errors are displayed.
This message is for
information only.
You can change the
system ID and name in
the System Setup
program (see "Entering
the System Setup
Program" on page 43).
E1000
FAILSAFE,
Call Support
Check the system event log
for critical failure events.
See "Getting Help" on
page 205.
E1114
Temp Ambient
Ambient system
temperature is out of
acceptable range.
See "Troubleshooting
System Cooling
Problems" on page 172.
E1118
CPU Temp
Interface
The BMC is unable to
determine the processor(s)
temperature status.
Consequently, the BMC
increases the processor fan
speed to maximum
as a precautionary measure.
Turn off power to the
system and restart the
system. If the problem
persists, see "Getting
Help" on page 205.
E1210
CMOS Batt
CMOS battery is missing, or
the voltage is out of
acceptable range.
See "Troubleshooting the
System Battery" on
page 170.
Summary of Contents for PowerEdge DR715
Page 10: ...10 Contents Glossary 207 Index 223 ...
Page 42: ...42 About Your System ...
Page 62: ...62 Using the System Setup Program ...
Page 158: ...158 Installing System Components ...
Page 192: ...192 Troubleshooting Your System ...
Page 204: ...204 Jumpers and Connectors ...
Page 206: ...206 Getting Help ...
Page 222: ...222 Glossary ...
Page 229: ...Index 229 W warning messages 41 warranty 11 wet system troubleshooting 168 ...