38
About Your System
ROM bad checksum
=
address
Expansion card improperly
installed or faulty.
Reseat the expansion card(s).
Ensure that all appropriate
cables are securely connected
to the expansion card(s). If
the problem persists, see
"Troubleshooting Expansion
Cards" on page 187.
SATA PORT x drive
not found
SATA port
x
was turned on in
setup, but a drive was not
found.
See "Troubleshooting a Hard
Drive" on page 181 for the
appropriate drive(s) installed
in your system.
Sector not found
Seek error
Seek operation
failed
Faulty hard drive, USB
device, or USB medium.
See "Troubleshooting a USB
Device" on page 165 or
"Troubleshooting a Hard
Drive" on page 181 for the
appropriate drive(s) installed
in your system.
Shutdown failure
Shutdown test failure.
See "Troubleshooting System
Memory" on page 174.
Spare bank
enabled
DIMM sparing has been
enabled.
Information only.
The amount of
system memory has
changed
Memory has been added or
removed or a memory
module may be faulty.
If memory has been added or
removed, this message is
informative and can be
ignored. If memory has not
been added or removed,
check the SEL to determine
if single-bit or multi-bit
errors were detected and
replace the faulty memory
module (see
"Troubleshooting System
Memory" on page 174).
Table 1-6.
System Messages
(continued)
Message
Causes
Corrective Actions
Summary of Contents for PowerEdge DR715
Page 10: ...10 Contents Glossary 207 Index 223 ...
Page 42: ...42 About Your System ...
Page 62: ...62 Using the System Setup Program ...
Page 158: ...158 Installing System Components ...
Page 192: ...192 Troubleshooting Your System ...
Page 204: ...204 Jumpers and Connectors ...
Page 206: ...206 Getting Help ...
Page 222: ...222 Glossary ...
Page 229: ...Index 229 W warning messages 41 warranty 11 wet system troubleshooting 168 ...
Page 230: ...230 Index ...