About Your System
25
E1620
PS # Input
Range
Power source for specified
power supply is unavailable,
or out of acceptable range.
Check the AC power
source for the specified
power supply. If the
problem persists, see
"Troubleshooting
Redundant Power
Supplies" on page 171.
E1624
PS Redundancy
The power supply subsystem
is no longer redundant. If
the last supply fails, the
system will go down.
See "Troubleshooting
Redundant Power
Supplies" on page 171.
E1625
PS AC Current
Power source is out of
acceptable range.
Check the AC power
source.
E1710
I/O Channel
Chk
The system BIOS has
reported an I/O channel
check.
See "Getting Help" on
page 205.
E1711
PCI PERR B##
D## F##
The system BIOS has
reported a PCI parity error
on a component that resides
in PCI configuration space
at bus ##, device ##,
function ##.
Remove and reseat the
PCIe expansion cards. If
the problem persists, see
"Troubleshooting
Expansion Cards" on
page 187.
PCI PERR Slot
#
The system BIOS has
reported a PCI parity error
on a component that resides
in the specified PCIe slot.
Remove and reseat the
PCIe expansion cards. If
the problem persists, see
"Troubleshooting
Expansion Cards" on
page 187.
Table 1-5.
LCD Status Messages
(continued)
Code
Text
Causes
Corrective Actions
Summary of Contents for PowerEdge DR715
Page 10: ...10 Contents Glossary 207 Index 223 ...
Page 42: ...42 About Your System ...
Page 62: ...62 Using the System Setup Program ...
Page 158: ...158 Installing System Components ...
Page 192: ...192 Troubleshooting Your System ...
Page 204: ...204 Jumpers and Connectors ...
Page 206: ...206 Getting Help ...
Page 222: ...222 Glossary ...
Page 229: ...Index 229 W warning messages 41 warranty 11 wet system troubleshooting 168 ...
Page 230: ...230 Index ...