About Your System
39
This system
supports only
Opteron(TM) 2000
series
processors
Microprocessor(s) is not
supported by the system.
Install a supported
microprocessor or
microprocessor combination
(see "Installing a Processor"
on page 136).
Time-of-day
clock stopped
Faulty battery or faulty chip. See "Troubleshooting the
System Battery" on page 170.
Time-of-day not
set - please run
SETUP program
Incorrect Time or Date
settings; faulty system
battery.
Check the Time and Date
settings (see "Entering the
System Setup Program" on
page 43). If the problem
persists, replace the system
battery (see "System Battery"
on page 138).
Timer chip
counter 2 failed
Faulty system board.
See "Getting Help" on
page 205.
TPM
configuration
operation
honored
System will now restart.
Information only.
TPM failure
A Trusted Platform Module
(TPM) function has failed.
See "Getting Help" on
page 205.
TPM operation is
pending. Press I
to Ignore or M to
Modify to allow
this change and
reset the system.
Configuration change has
been requested.
Press
I
to continue system
boot. Press
M
to modify the
TPM setting and restart.
Unexpected
interrupt in
protected mode
DIMMs are improperly
seated or the keyboard/mouse
controller chip has failed.
Reseat the DIMMs (see
"Troubleshooting System
Memory" on page 174). If the
problem persists, see
"Getting Help" on page 205.
Table 1-6.
System Messages
(continued)
Message
Causes
Corrective Actions
Summary of Contents for PowerEdge DR715
Page 10: ...10 Contents Glossary 207 Index 223 ...
Page 42: ...42 About Your System ...
Page 62: ...62 Using the System Setup Program ...
Page 158: ...158 Installing System Components ...
Page 192: ...192 Troubleshooting Your System ...
Page 204: ...204 Jumpers and Connectors ...
Page 206: ...206 Getting Help ...
Page 222: ...222 Glossary ...
Page 229: ...Index 229 W warning messages 41 warranty 11 wet system troubleshooting 168 ...
Page 230: ...230 Index ...