AUSTROMAT
®
624 / 644
5. User interface
Operating Instructions (Version 01/2012)
97
Perform the tightness test
After the program starts, the firing chamber is closed, heated and evacuated. When the
maximum vacuum is achieved, the prompt "Flood chamber?" appears. Monitor the pressure
display over approximately two minutes. A rise in pressure of about 20 mbar over two minutes
(10 mbar/min) is normal and means that the firing furnace is vacuum-tight. You can now click
[OK] in the "Flood chamber?" window. The firing chamber is ventilated and then opened.
When you observe a much higher rise in pressure: Clean and check all the components of the
vacuum system (replace the seals and hoses if necessary), and repeat the tightness test.
NOTE:
Always coat the sealing ring on the lift seat (O-ring) with talcum powder after cleaning so
that the lift seat does not hold to the firing furnace housing.
5.7.3.5. Transport safety lock
NOTE:
Before transporting:
•
Let the firing furnace and insulation table cool off,
•
Remove the insulation table,
•
Close the firing chamber.
Toe "Transport bracing" function protects the components inside the firing furnace during
transportation. The following message appears.
Fig. 5-33
Setup > Transport bracing
Run the function before transporting the firing furnace. Sensitive components are held in the
firing furnace and protected from damage to a greater degree during transportation.
Summary of Contents for AUSTROMAT 624
Page 1: ...Operating Instructions AUSTROMAT 624 644 Version 01 2012 ...
Page 8: ...Table Of Contents AUSTROMAT 624 644 8 Operating Instructions Version 01 2012 ...
Page 146: ...9 Appendix AUSTROMAT 624 644 146 Operating Instructions Version 01 2012 ...
Page 147: ...AUSTROMAT 624 644 9 Appendix Operating Instructions Version 01 2012 147 ...
Page 148: ...9 Appendix AUSTROMAT 624 644 148 Operating Instructions Version 01 2012 ...
Page 149: ...AUSTROMAT 624 644 9 Appendix Operating Instructions Version 01 2012 149 ...
Page 150: ...9 Appendix AUSTROMAT 624 644 150 Operating Instructions Version 01 2012 ...
Page 151: ...AUSTROMAT 624 644 9 Appendix Operating Instructions Version 01 2012 151 ...
Page 152: ...9 Appendix AUSTROMAT 624 644 152 Operating Instructions Version 01 2012 ...
Page 155: ...AUSTROMAT 624 644 10 Index Operating Instructions Version 01 2012 155 ...