5. User interface
AUSTROMAT
®
624 / 644
74
Operating Instructions (Version 01/2012)
Program step
Temperature in °C
Temperature rise in
°C/min or pressing
parameters
Holding time
in min:sec
Starting temperature 100 … 700
End temperature
700 … 1200
0 … MAX
1)
00:00
…
99:59
Pressing time
[Auto]
2)
00:00
…
99:59
Pressure level
0 … 7
3)
Tab. 5-8
Permissible value range of the program steps for easy programs
1) maximum rise for input 0°C/min
2) Automatic press time shortening
3) The appendix contains a table with the pressures
For programming examples, go to the download area of the DEKEMA website: