u.
Press either
COM
or
ENTER
to display the word "TER" (for "TERMINATOR").
The OUTPUT TERMINATOR—also called "END-OF-TRANSMISSION TERMINA-
TOR (EOT)"—is a string of up to four ASCII CONTROL CHARACTERS from [00]
through [1F] to be transmitted at the end of each complete transmission from
the RS-232/485 Interface Port (in either RS-232 or RS-485 mode)—including
every response to a received MNEMONIC COMMAND (see Appendix B).
v.
If you don't want to display the OUTPUT TERMINATOR, press the
COM
button
again and proceed to Step a', below. To display the first character of the OUT-
PUT TERMINATOR, press
ENTER
. The unit will display
w. Press
ENTER
again.* The unit will show a two-character hexadecimal word in
square brackets. For example, if the first character of the OUTPUT TERMINA-
TOR is currently LINE FEED ([LF]), the unit will display
x.
To change the first character of the OUTPUT TERMINATOR, you can cycle for-
wards or backwards through allowed values of each active digit by pressing
its top or bottom segment, respectively. NOTE: The instrument will not accept
an OUTPUT TERMINATOR character entry greater that "1F," even though it is
possible to increment the most significant digit up to "7."**
y.
When the desired character appears, press
ENTER
. The unit will display
Eot2
. Press
ENTER
to display the second character of the OUTPUT TERMI-
NATOR. Change it as you did for the first character, and press
ENTER
. The
unit will display
EOT3
. Proceed as above to change the third and fourth char-
acters of the OUTPUT TERMINATOR, if required.
z.
When the final character of the OUTPUT TERMINATOR has been entered, you
will return to the "OUTPUT" display. Press the
COM
button twice. The unit will
display the word "BAUD." It has now cycled through all the communications
parameters.
a'. Press
SETUP
to return to the "Setup" display, from which you can proceed to
enter more setup values or exit SETUP MODE altogether.
NOTE: IF YOU ONLY HAVE TO CHANGE ONE COMMUNICATIONS SETUP PARA-
METER, YOU CAN QUICKLY STEP THROUGH THE SERIES BY KEEPING YOUR
FINGER ON THE
COM
BUTTON UNTIL THE PARAMETER OF INTEREST
APPEARS. THEN RELEASE THE
COM
BUTTON AND PRESS
ENTER
TO DISPLAY
THAT PARAMETER'S CURRENT VALUE.
3.6
3
S
ETUP
: I
NSTRUMENT
C
ONFIGURATION
3.a C
ONFIGURING
T
HROUGH THE
F
RONT
P
ANEL
* Pressing the
COM
button at this point would step to the display of
Eot2
, etc.
** For the significance of an "EOT" character of
[00]
, see the
EOT
command, Section 3.b.
Summary of Contents for 3500 Series
Page 1: ...3500 INSTRUMENT SERIES SB 3 INSTRUCTION MANUAL...
Page 38: ...2 20 This page intentionally blank...
Page 84: ...4 22 This page intentionally blank...
Page 92: ...5 8 This page intentionally blank...
Page 112: ...B 12 This page intentionally blank...
Page 114: ...C 2 This page intentionally blank...
Page 121: ...F 3 This page intentionally blank...