6.3.18 17-** Motor Feedb.Option
Par.
No. #
Parameter description
Default value
4-set-up
Change
during
operation
Conver-
sion index
Type
17-1* Inc. Enc. Interface
17-10 Signal Type
[1] TTL (5V, RS4222)
All set-ups
FALSE
-
Uint8
17-11 Resolution (PPR)
1024 N/A
All set-ups
FALSE
0
Uint16
17-2* Abs. Enc. Interface
17-20 Protocol Selection
[0] None
All set-ups
FALSE
-
Uint8
17-21 Resolution (Positions/Rev)
ExpressionLimit
All set-ups
FALSE
0
Uint32
17-24 SSI Data Length
13 N/A
All set-ups
FALSE
0
Uint8
17-25 Clock Rate
ExpressionLimit
All set-ups
FALSE
3
Uint16
17-26 SSI Data Format
[0] Gray code
All set-ups
FALSE
-
Uint8
17-34 HIPERFACE Baud rate
[4] 9600
All set-ups
FALSE
-
Uint8
17-5* Resolver Interface
17-50 Poles
2 N/A
1 set-up
FALSE
0
Uint8
17-51 Input Voltage
7 V
1 set-up
FALSE
-1
Uint8
17-52 Input Frequency
10 kHz
1 set-up
FALSE
2
Uint8
17-53 Transformation Ratio
0.5 N/A
1 set-up
FALSE
-1
Uint8
17-56 Encoder Sim. Resolution
[0] Disabled
1 set-up
FALSE
-
Uint8
17-59 Resolver Interface
[0] Disabled
All set-ups
FALSE
-
Uint8
17-6* Monitoring and App.
17-60 Feedback Direction
[0] Clockwise
All set-ups
FALSE
-
Uint8
17-61 Feedback Signal Monitoring
[1] Warning
All set-ups
TRUE
-
Uint8
6.3.19 18-** Data Readouts 2
Par.
No. #
Parameter description
Default value
4-set-up
Change
during
operation
Conver-
sion index
Type
18-3* Analog Readouts
18-36 Analog Input X48/2 [mA]
0 N/A
All set-ups
TRUE
-3
Int32
18-37 Temp. Input X48/4
0 N/A
All set-ups
TRUE
0
Int16
18-38 Temp. Input X48/7
0 N/A
All set-ups
TRUE
0
Int16
18-39 Temp. Input X48/10
0 N/A
All set-ups
TRUE
0
Int16
18-6* Inputs & Outputs 2
18-60 Digital Input 2
0 N/A
All set-ups
FALSE
0
Uint16
18-9* PID Readouts
18-90 Process PID Error
0 %
All set-ups
FALSE
-1
Int16
18-91 Process PID Output
0 %
All set-ups
FALSE
-1
Int16
18-92 Process PID Clamped Output
0 %
All set-ups
FALSE
-1
Int16
18-93 Process PID Gain Scaled Output
0 %
All set-ups
FALSE
-1
Int16
Programming