[Off]
Stops the connected motor (when pressed on the
adjustable frequency drive LCP) or the filter (when pressed
on the filter LCP). The key can be
[1] Enabled
or
[0]
Disabled
via
0-41 [Off] Key on LCP
. If no external stop
function is selected and the [Off] key is inactive, the motor
can only be stopped by disconnecting the line power
supply.
[Auto On]
Enables the adjustable frequency drive to be controlled via
the control terminals and/or serial communication. When a
start signal is applied on the control terminals and/or the
bus, the adjustable frequency drive starts. The key can be
[1] Enabled
or
[0] Disabled
via
0-42 [Auto on] Key on LCP
.
NOTICE!
An active HAND-OFF-AUTO signal via the digital inputs
has higher priority than the control keys [Hand On] –
[Auto On].
[Reset]
Is used for resetting the adjustable frequency drive or filter
after an alarm (trip). The key can be
[1] Enabled
or
[0]
Disabled
via
0-43 [Reset] Key on LCP
on the LCP. Reset
The parameter shortcut
Can be carried out by holding down the [Main Menu] key
for 3 seconds. The parameter shortcut allows direct access
to any parameter.
5.1.3 Changing Data
1.
Press [Quick Menu] or [Main Menu].
2.
Use [
▲
] and [
▼
] to find parameter group to edit.
Changing data
3.
Press [OK].
4.
Use [
▲
] and [
▼
] to find parameter to edit.
5.
Press [OK].
6.
Use [
▲
] and [
▼
] to select correct parameter
setting. Or, to move to digits within a number,
use [
◄
] and [
►
]. The cursor indicates the digit
selected to be changed. The [
▲
] key increases the
value, the [
▼
] key decreases the value.
7.
Press [Cancel] to ignore the change, or press [OK]
to accept the change and enter a new setting.
5.1.4 Changing a Text Value
If the selected parameter is a text value, change the text
value by using the [
▲
]/[
▼
] keys.
[
▲
] increases the value, and [
▼
] decreases the value. Place
the cursor on the value to be saved and press [OK].
130BP068.10
740RPM
0 -01 Language
[0] English
10.64 A
1 [1]
0-0*
Basic Settings
Figure 5.13 Display Example
5.1.5 Changing a Group of Numeric Data
Values
If the selected parameter represents a numeric data value,
change the selected data value pressing the [
◄
] and [
►
]
navigation keys as well as [
▲
] and [
▼
] keys. Press [
◄
] and
[
►
] to move the cursor horizontally.
130BP069.10
1- 6*
113 RPM 1.78 A 1(1)
Load depen. setting
1 - 60 Low speed load
compensation
1
0
0%
Figure 5.14 Display Example
Press [
▲
]/[
▼
] to change the data value. [
▲
] enlarges the
data value, and [
▼
] reduces the data value. Place the
cursor on the value to be saved and press [OK].
130BP070.10
1 - 60 Low speed load
compensation
1 0%
Load depen. setting
1- 6*
729RPM
6.21A 1(1)
6
Figure 5.15 Display Example
User Interface
Instruction Manual
48
Danfoss A/S © Rev. 2014-02-07 All rights reserved.
MG37A222
5
5
Summary of Contents for VLT AutomationDrive FC 302