6.3.22 33-** MCO Adv. Settings
Par.
No. #
Parameter description
Default value
4-set-up
Change
during
operation
Conver-
sion index
Type
33-0* Home Motion
33-00 Force HOME
[0] Home not forced
2 set-ups
TRUE
-
Uint8
33-01 Zero Point Offset from Home Pos.
0 N/A
2 set-ups
TRUE
0
Int32
33-02 Ramp for Home Motion
10 N/A
2 set-ups
TRUE
0
Uint32
33-03 Velocity of Home Motion
10 N/A
2 set-ups
TRUE
0
Int32
33-04 Behavior during Home Motion
[0] Reverse and index
2 set-ups
TRUE
-
Uint8
33-1* Synchronization
33-10 Sync Factor Master
1 N/A
2 set-ups
TRUE
0
Int32
33-11 Sync Factor Slave
1 N/A
2 set-ups
TRUE
0
Int32
33-12 Position Offset for Synchronization
0 N/A
2 set-ups
TRUE
0
Int32
33-13 Accuracy Window for Position Sync.
1000 N/A
2 set-ups
TRUE
0
Int32
33-14 Relative Slave Velocity Limit
0 %
2 set-ups
TRUE
0
Uint8
33-15 Marker Number for Master
1 N/A
2 set-ups
TRUE
0
Uint16
33-16 Marker Number for Slave
1 N/A
2 set-ups
TRUE
0
Uint16
33-17 Master Marker Distance
4096 N/A
2 set-ups
TRUE
0
Uint32
33-18 Slave Marker Distance
4096 N/A
2 set-ups
TRUE
0
Uint32
33-19 Master Marker Type
[0] Encoder Z positive
2 set-ups
TRUE
-
Uint8
33-20 Slave Marker Type
[0] Encoder Z positive
2 set-ups
TRUE
-
Uint8
33-21 Master Marker Tolerance Window
0 N/A
2 set-ups
TRUE
0
Uint32
33-22 Slave Marker Tolerance Window
0 N/A
2 set-ups
TRUE
0
Uint32
33-23 Start Behavior for Marker Sync
[0] Leading marker
2 set-ups
TRUE
-
Uint16
33-24 Marker Number for Fault
10 N/A
2 set-ups
TRUE
0
Uint16
33-25 Marker Number for Ready
1 N/A
2 set-ups
TRUE
0
Uint16
33-26 Velocity Filter
0 us
2 set-ups
TRUE
-6
Int32
33-27 Offset Filter Time
0 ms
2 set-ups
TRUE
-3
Uint32
33-28 Marker Filter Configuration
[0] Marker filter 1
2 set-ups
TRUE
-
Uint8
33-29 Filter Time for Marker Filter
0 ms
2 set-ups
TRUE
-3
Int32
33-30 Maximum Marker Correction
0 N/A
2 set-ups
TRUE
0
Uint32
33-31 Synchronization Type
[0] Standard
2 set-ups
TRUE
-
Uint8
33-32 Feed Forward Velocity Adaptation
0 N/A
2 set-ups
TRUE
0
Uint32
33-33 Velocity Filter Window
0 N/A
2 set-ups
TRUE
0
Uint32
33-34 Slave Marker filter time
0 ms
2 set-ups
TRUE
-3
Uint32
33-4* Limit Handling
33-40 Behavior at End Limit Switch
[0] Call error handler
2 set-ups
TRUE
-
Uint8
33-41 Negative Software End Limit
-500000 N/A
2 set-ups
TRUE
0
Int32
33-42 Positive Software End Limit
500000 N/A
2 set-ups
TRUE
0
Int32
33-43 Negative Software End Limit Active
[0] Inactive
2 set-ups
TRUE
-
Uint8
33-44 Positive Software End Limit Active
[0] Inactive
2 set-ups
TRUE
-
Uint8
33-45 Time in Target Window
0 ms
2 set-ups
TRUE
-3
Uint8
33-46 Target Window LimitValue
1 N/A
2 set-ups
TRUE
0
Uint16
33-47 Size of Target Window
0 N/A
2 set-ups
TRUE
0
Uint16
33-5* I/O Configuration
33-50 Terminal X57/1 Digital Input
[0] No function
2 set-ups
TRUE
-
Uint8
33-51 Terminal X57/2 Digital Input
[0] No function
2 set-ups
TRUE
-
Uint8
33-52 Terminal X57/3 Digital Input
[0] No function
2 set-ups
TRUE
-
Uint8
33-53 Terminal X57/4 Digital Input
[0] No function
2 set-ups
TRUE
-
Uint8
33-54 Terminal X57/5 Digital Input
[0] No function
2 set-ups
TRUE
-
Uint8
33-55 Terminal X57/6 Digital Input
[0] No function
2 set-ups
TRUE
-
Uint8
33-56 Terminal X57/7 Digital Input
[0] No function
2 set-ups
TRUE
-
Uint8
33-57 Terminal X57/8 Digital Input
[0] No function
2 set-ups
TRUE
-
Uint8
33-58 Terminal X57/9 Digital Input
[0] No function
2 set-ups
TRUE
-
Uint8
33-59 Terminal X57/10 Digital Input
[0] No function
2 set-ups
TRUE
-
Uint8
33-60 Terminal X59/1 and X59/2 Mode
[1] Output
2 set-ups
FALSE
-
Uint8
33-61 Terminal X59/1 Digital Input
[0] No function
2 set-ups
TRUE
-
Uint8
33-62 Terminal X59/2 Digital Input
[0] No function
2 set-ups
TRUE
-
Uint8
33-63 Terminal X59/1 Digital Output
[0] No function
2 set-ups
TRUE
-
Uint8
33-64 Terminal X59/2 Digital Output
[0] No function
2 set-ups
TRUE
-
Uint8
Programming
Instruction Manual
106
Danfoss A/S © Rev. 2014-02-07 All rights reserved.
MG37A222
6
6