6.3.20 30-** Special Features
Par.
No. #
Parameter description
Default value
4-set-up
FC
302
only
Change
during
operation
Conver-
sion index
Type
30-0* Wobbler
30-00
Wobble Mode
[0] Abs. Freq., Abs. Time
All set-ups
FALSE
-
Uint8
30-01
Wobble Delta Frequency [Hz]
5 Hz
All set-ups
TRUE
-1
Uint8
30-02
Wobble Delta Frequency [%]
25 %
All set-ups
TRUE
0
Uint8
30-03
Wobble Delta Freq. Scaling Resource
[0] No function
All set-ups
TRUE
-
Uint8
30-04
Wobble Jump Frequency [Hz]
0 Hz
All set-ups
TRUE
-1
Uint8
30-05
Wobble Jump Frequency [%]
0 %
All set-ups
TRUE
0
Uint8
30-06
Wobble Jump Time
ExpressionLimit
All set-ups
TRUE
-3
Uint16
30-07
Wobble Sequence Time
10 s
All set-ups
TRUE
-1
Uint16
30-08
Wobble Up/Down Time
5 s
All set-ups
TRUE
-1
Uint16
30-09
Wobble Random Function
[0] Off
All set-ups
TRUE
-
Uint8
30-10
Wobble Ratio
1 N/A
All set-ups
TRUE
-1
Uint8
30-11
Wobble Random Ratio Max.
10 N/A
All set-ups
TRUE
-1
Uint8
30-12
Wobble Random Ratio Min.
0.1 N/A
All set-ups
TRUE
-1
Uint8
30-19
Wobble Delta Freq. Scaled
0 Hz
All set-ups
FALSE
-1
Uint16
30-2* Adv. Start Adjust
30-20
High Starting Torque Time [s]
ExpressionLimit
All set-ups
x
TRUE
-2
Uint16
30-21
High Starting Torque Current [%]
ExpressionLimit
All set-ups
x
TRUE
-1
Uint32
30-22
Locked Rotor Protection
ExpressionLimit
All set-ups
x
TRUE
-
Uint8
30-23
Locked Rotor Detection Time [s]
ExpressionLimit
All set-ups
x
TRUE
-2
Uint8
30-8* Compatibility (I)
30-80
d-axis inductance (Ld)
ExpressionLimit
All set-ups
x
FALSE
-6
Int32
30-81
Brake Resistor (ohm)
ExpressionLimit
1 set-up
TRUE
-2
Uint32
30-83
Speed PID Proportional Gain
ExpressionLimit
All set-ups
TRUE
-4
Uint32
30-84
Process PID Proportional Gain
0.100 N/A
All set-ups
TRUE
-3
Uint16
Programming
Instruction Manual
MG37A222
Danfoss A/S © Rev. 2014-02-07 All rights reserved.
103
6
6