Par. No. #
Parameter description
Default value
2-set-up
Change
during
operation
Conversion
index
Type
15-51
Drive Serial Number
0 N/A
1 set-up
FALSE
0
VisStr[13]
15-53
Power Card Serial Number
0 N/A
1 set-up
FALSE
0
VisStr[21]
15-6* Option Ident
15-60
Option Mounted
ExpressionLimit
All set-ups
FALSE
0
VisStr[30]
15-61
Option SW Version
ExpressionLimit
All set-ups
FALSE
0
VisStr[20]
15-62
Option Ordering No
ExpressionLimit
All set-ups
FALSE
0
VisStr[8]
15-63
Option Serial No
ExpressionLimit
All set-ups
FALSE
0
VisStr[18]
15-70
Option in Slot A
0 N/A
All set-ups
FALSE
0
VisStr[30]
15-71
Slot A Option SW Version
0 N/A
All set-ups
FALSE
0
VisStr[20]
15-9* Parameter Info
15-92
Defined Parameters
0 N/A
1 set-up
TRUE
0
Uint16
15-97
Application Type
0 N/A
1 set-up
TRUE
0
Uint32
15-98
Drive Identification
0 N/A
1 set-up
FALSE
0
VisStr[56]
15-99
Parameter Metadata
0 N/A
1 set-up
FALSE
0
Uint16
5.2.15 16-** Data Readouts
Par. No. #
Parameter description
Default value
2-set-up
Change
during
operation
Conversion
index
Type
16-0* General Status
16-00
Control Word
0 N/A
1 set-up
TRUE
0
Uint16
16-01
Reference [Unit]
0 ReferenceFeedbackUnit
1 set-up
TRUE
-3
Int32
16-02
Reference [%]
0%
1 set-up
TRUE
-1
Int16
16-03
Status Word
0 N/A
1 set-up
TRUE
0
Uint16
16-05
Main Actual Value [%]
0%
1 set-up
TRUE
-2
Int16
16-09
Custom Readout
0 CustomReadoutUnit
1 set-up
TRUE
-2
Int32
16-1* Motor Status
16-10
Power [kW]
0 kW
1 set-up
TRUE
-3
Uint32
16-11
Power [hp]
0 hp
1 set-up
TRUE
-3
Uint32
16-12
Motor Voltage
0 V
1 set-up
TRUE
-1
Uint32
16-13
Frequency
0 Hz
1 set-up
TRUE
-1
Uint32
16-14
Motor current
0 A
1 set-up
TRUE
-2
Uint16
16-15
Frequency [%]
0%
1 set-up
TRUE
-1
Uint16
16-16
Torque [Nm]
0 Nm
All set-ups
FALSE
-1
Int32
16-18
Motor Thermal
0%
1 set-up
TRUE
0
Uint8
16-22
Torque [%]
0%
All set-ups
FALSE
0
Int16
16-3* Drive Status
16-30
DC Link Voltage
0 V
1 set-up
TRUE
0
Uint32
16-33
Brake Energy /2 min
0 kW
All set-ups
FALSE
0
Uint32
16-34
Heatsink Temp.
0 °C
1 set-up
TRUE
100
Int8
16-35
Inverter Thermal
0%
1 set-up
TRUE
0
Uint8
16-36
Inv. Nom. Current
0 A
1 set-up
TRUE
-2
Uint16
16-37
Inv. Max. Current
0 A
1 set-up
TRUE
-2
Uint16
16-38
SL Controller State
0 N/A
1 set-up
TRUE
0
Uint8
16-39
Control Card Temp.
0 °C
All set-ups
FALSE
100
Uint16
16-5* Ref. & Feedb.
16-50
External Reference
0%
1 set-up
TRUE
-1
Int16
16-52
Feedback[Unit]
0 ProcessCtrlUnit
1 set-up
TRUE
-3
Int32
16-53
Digi Pot Reference
0 N/A
All set-ups
FALSE
-2
Int16
Parameter Lists
VLT
®
AutomationDrive FC 360
136
Danfoss A/S © 7/2015 All rights reserved.
MG06C602