Par. No. # Parameter description
Default value
2-set-up
Change
during
operation
Conversion
index
Type
5-3* Digital Outputs
5-30
Terminal 27 Digital Output
[0] No operation
All set-ups
TRUE
–
Uint8
5-31
Terminal 29 Digital Output
[0] No operation
All set-ups
TRUE
–
Uint8
5-34
On Delay, Digital Output
0.01 s
All set-ups
TRUE
-2
Uint16
5-35
Off Delay, Digital Output
0.01 s
All set-ups
TRUE
-2
Uint16
5-4* Relays
5-40
Function Relay
ExpressionLimit
All set-ups
TRUE
–
Uint8
5-41
On Delay, Relay
0.01 s
All set-ups
TRUE
-2
Uint16
5-42
Off Delay, Relay
0.01 s
All set-ups
TRUE
-2
Uint16
5-5* Pulse Input
5-50
Term. 29 Low Frequency
4 Hz
All set-ups
TRUE
0
Uint32
5-51
Term. 29 High Frequency
32000 Hz
All set-ups
TRUE
0
Uint32
5-52
Term. 29 Low Ref./Feedb. Value
0 N/A
All set-ups
TRUE
-3
Int32
5-53
Term. 29 High Ref./Feedb. Value
ExpressionLimit
All set-ups
TRUE
-3
Int32
5-55
Term. 33 Low Frequency
4 Hz
All set-ups
TRUE
0
Uint32
5-56
Term. 33 High Frequency
32000 Hz
All set-ups
TRUE
0
Uint32
5-57
Term. 33 Low Ref./Feedb. Value
0 N/A
All set-ups
TRUE
-3
Int32
5-58
Term. 33 High Ref./Feedb. Value
ExpressionLimit
All set-ups
TRUE
-3
Int32
5-6* Pulse Output
5-60
Terminal 27 Pulse Output Variable
[0] No operation
All set-ups
TRUE
–
Uint8
5-62
Pulse Output Max Freq 27
5000 Hz
All set-ups
TRUE
0
Uint32
5-63
Terminal 29 Pulse Output Variable
[0] No operation
All set-ups
TRUE
–
Uint8
5-65
Pulse Output Max Freq 29
5000 Hz
All set-ups
TRUE
0
Uint32
5-7* 24 V Encoder Input
5-70
Term 32/33 Pulses Per Revolution
1024 N/A
All set-ups
FALSE
0
Uint16
5-71
Term 32/33 Encoder Direction
[0] Clockwise
All set-ups
FALSE
–
Uint8
5-9* Bus Controlled
5-90
Digital & Relay Bus Control
0 N/A
All set-ups
TRUE
0
Uint32
5-93
Pulse Out 27 Bus Control
0%
All set-ups
TRUE
-2
Uint16
5-94
Pulse Out 27 Timeout Preset
0%
1 set-up
TRUE
-2
Uint16
5-95
Pulse Out 29 Bus Control
0%
All set-ups
TRUE
-2
Uint16
5-96
Pulse Out 29 Timeout Preset
0%
1 set-up
TRUE
-2
Uint16
5.2.7 6-** Analog In/Out
Par. No. # Parameter description
Default value
2-set-up
Change
during
operation
Conversion
index
Type
6-0* Analog I/O Mode
6-00
Live Zero Timeout Time
10 s
All set-ups
TRUE
0
Uint8
6-01
Live Zero Timeout Function
[0] Off
All set-ups
TRUE
–
Uint8
6-1* Analog Input 53
6-10
Terminal 53 Low Voltage
0.07 V
All set-ups
TRUE
-2
Uint16
6-11
Terminal 53 High Voltage
10 V
All set-ups
TRUE
-2
Uint16
6-12
Terminal 53 Low Current
4 mA
All set-ups
TRUE
-5
Uint16
6-13
Terminal 53 High Current
20 mA
All set-ups
TRUE
-5
Uint16
6-14
Terminal 53 Low Ref./Feedb. Value
0 N/A
All set-ups
TRUE
-3
Int32
6-15
Terminal 53 High Ref./Feedb. Value
ExpressionLimit
All set-ups
TRUE
-3
Int32
6-16
Terminal 53 Filter Time Constant
0.01 s
All set-ups
TRUE
-2
Uint16
6-19
Terminal 53 mode
[1] Voltage mode
1 set-up
TRUE
–
Uint8
6-2* Analog Input 54
Parameter Lists
Programming Guide
MG06C602