Par. No. # Parameter description
Default value
2-set-up
Change
during
operation
Conversion
index
Type
8-50
Coasting Select
[3] Logic OR
All set-ups
TRUE
–
Uint8
8-51
Quick Stop Select
[3] Logic OR
All set-ups
TRUE
–
Uint8
8-52
DC Brake Select
[3] Logic OR
All set-ups
TRUE
–
Uint8
8-53
Start Select
[3] Logic OR
All set-ups
TRUE
–
Uint8
8-54
Reversing Select
[3] Logic OR
All set-ups
TRUE
–
Uint8
8-55
Set-up Select
[3] Logic OR
All set-ups
TRUE
–
Uint8
8-56
Preset Reference Select
[3] Logic OR
All set-ups
TRUE
–
Uint8
8-57
PROFIdrive OFF2 Select
[3] Logic OR
All set-ups
TRUE
–
Uint8
8-58
PROFIdrive OFF3 Select
[3] Logic OR
All set-ups
TRUE
–
Uint8
8-7* Protocol Firmware Version
8-79
Protocol Firmware version
ExpressionLimit
1 set-up
FALSE
-2
Uint16
8-8* FC Port Diagnostics
8-80
Bus Message Count
0 N/A
1 set-up
TRUE
0
Uint32
8-81
Bus Error Count
0 N/A
1 set-up
TRUE
0
Uint32
8-82
Slave Messages Rcvd
0 N/A
1 set-up
TRUE
0
Uint32
8-83
Slave Error Count
0 N/A
1 set-up
TRUE
0
Uint32
8-84
Slave Messages Sent
0 N/A
1 set-up
TRUE
0
Uint32
8-85
Slave Timeout Errors
0 N/A
1 set-up
TRUE
0
Uint32
8-88
Reset FC port Diagnostics
[0] Do not reset
1 set-up
TRUE
–
Uint8
8-9* Bus Feedback
8-90
Bus Jog 1 Speed
100 RPM
All set-ups
TRUE
67
Uint16
8-91
Bus Jog 2 Speed
200 RPM
All set-ups
TRUE
67
Uint16
5.2.10 9-** PROFIdrive
Par. No. #
Parameter description
Default value
2-set-up
Change
during
operation
Conversion
index
Type
9-00
Setpoint
0 N/A
All set-ups
TRUE
0
Uint16
9-07
Actual Value
0 N/A
All set-ups
FALSE
0
Uint16
9-15
PCD Write Configuration
ExpressionLimit
1 set-up
TRUE
–
Uint16
9-16
PCD Read Configuration
ExpressionLimit
1 set-up
TRUE
–
Uint16
9-18
Node Address
126 N/A
1 set-up
TRUE
0
Uint8
9-19
Drive Unit System Number
1037 N/A
All set-ups
TRUE
0
Uint16
9-22
Telegram Selection
[100] None
1 set-up
TRUE
–
Uint8
9-23
Parameters for Signals
0
All set-ups
TRUE
–
Uint16
9-27
Parameter Edit
[1] Enabled
1 set-up
FALSE
–
Uint16
9-28
Process Control
[1] Enable cyclic master
1 set-up
FALSE
–
Uint8
9-44
Fault Message Counter
0 N/A
All set-ups
TRUE
0
Uint16
9-45
Fault Code
0 N/A
All set-ups
TRUE
0
Uint16
9-47
Fault Number
0 N/A
All set-ups
TRUE
0
Uint16
9-52
Fault Situation Counter
0 N/A
All set-ups
TRUE
0
Uint16
9-53
PROFIBUS Warning Word
0 N/A
All set-ups
TRUE
0
V2
9-63
Actual Baud Rate
[255] No baudrate found
All set-ups
TRUE
–
Uint8
9-64
Device Identification
0 N/A
All set-ups
TRUE
0
Uint16
9-65
Profile Number
0 N/A
All set-ups
TRUE
0
OctStr[0]
9-67
Control Word 1
0 N/A
All set-ups
TRUE
0
V2
9-68
Status Word 1
0 N/A
All set-ups
TRUE
0
V2
9-70
Programming Set-up
[9] Active Set-up
1 set-up
TRUE
–
Uint8
9-71
PROFIBUS Save Data Values
[0] Off
All set-ups
TRUE
–
Uint8
9-72
PROFIBUSDriveReset
[0] No action
1 set-up
FALSE
–
Uint8
Parameter Lists
VLT
®
AutomationDrive FC 360
132
Danfoss A/S © 7/2015 All rights reserved.