Description of parameters
vacon · 79
24-hour support: +358 (0)201 212 575 • Email: [email protected]
5
2.5.4.3
Iout 1 Filter Time
2.5.5.3
Iout 2 Filter Time
2.5.6.3
Iout 3 Filter Time
Defines the filtering time of the analogue output signal. Setting this parameter value 0
will deactivate the filtering. First order filtering is used for the analogue output signals.
Figure 25.
2.5.4.4
Iout 1 Invert
2.5.5.4
Iout 2 Invert
2.5.6.4
Iout 3 Invert
Inverts the analogue output signal:
•
Maximum output signal = Minimum set value.
•
Minimum output signal = Maximum set value.
100 %
0 %
Analogue
Output
Function
Signal
0 %
100 %
Figure 26.
0
2000
4000
6000
8000
10000
12000
-0,045
0,
54
5
1,
13
5
1,
72
5
2,
31
5
2,
90
5
3,
49
5
4,
08
5
4,
67
5
5,
26
5
5,
85
5
6,
44
5
Unfiltered
1 s filter time
63 %