32 · vacon
Monitoring signals
Tel. +358 (0)201 2121 • Fax: +358 (0)201 2121 205
3
3.2.4
I/O monitoring values
V1.4.1
DIN1, DIN2, DIN3
ID 15
V1.4.2
DIN4, DIN5, DIN6
ID 16
DIN1/DIN2/DIN3 status
DIN4/DIN5/DIN6 status
b0
DIN3 DIN6
b1
DIN2 DIN5
b2
DIN1 DIN4
V1.4.3
DIN Status 1
ID 56
V1.4.4
DIN Status 2
ID 57
DIN StatusWord 1
DIN StatusWord 2
b0
DIN: A.1
DIN: C.5
b1
DIN: A.2
DIN: C.6
b2
DIN: A.3
DIN: D.1
b3
DIN: A.4
DIN: D.2
b4
DIN: A.5
DIN: D.3
b5
DIN: A.6
DIN: D.4
b6
DIN: B.1
DIN: D.5
b7
DIN: B.2
DIN: D.6
b8
DIN: B.3
DIN: E.1
b9
DIN: B.4
DIN: E.2
b10
DIN: B.5
DIN: E.3
b11
DIN: B.6
DIN: E.4
b12
DIN: C.1
DIN: E.5
b13
DIN: C.2
DIN: E.6
b14
DIN: C.3
b15
DIN: C.4
V1.4.5
Analogue Input 1
%
ID13
V1.4.6
Analogue Input 2
%
ID14
V1.4.7
Analogue input 3
%
ID 27
V1.4.8
Analogue Input 4
%
ID28
The unfiltered analogue input level.
0% = 0 mA / 0 V, -100% = -10 V, 100% = 20 mA / 10 V. Monitoring scaling is determined by
the option board parameter. It is possible to adjust this input value from fieldbus when
the input terminal selection is 0.1. This way it is possible to adjust the free analogue
input from fieldbus and have all the analogue input functions available for fieldbus
process data.
V1.4.9
Analogue Out 1 %
ID 26
V1.4.10
Analogue Out 2 %
ID 50
V1.4.11
Analogue Out 3 %
ID 51
Analogue Output value 0% = 0 mA / 0 V, 100% = 20 mA / 10 V