54 · vacon
Parameter list
Tel. +358 (0)201 2121 • Fax: +358 (0)201 2121 205
4
4.14
ID control functions
4.14.1
Value control
Table 43.
Power reference input signal selection, G2.2.8
Code
Parameter
Min
Max
Unit
Default
Cust
ID
Description
P2.14.1.1
Control Input Signal
ID
0 10000
ID 0
1580
P2.14.1.2
Control Input Off
Limit
-32000 32000
0
1581
P2.14.1.3
Control Input On
Limit
-32000 32000
0
1582
P2.14.1.4
Control Output Off
Value
-32000 32000
0
1583
P2.14.1.5
Control Output On
Value
-32000 32000
0
1584
P2.14.1.6
Control Output Signal
ID
0 10000
ID 0
1585
P2.14.1.7 Control
Mode
0
5
0
1586
0 = SR ABS
1 = Scale ABS
2 = Scale INV ABS
3 = SR
4 = Scale
5 = Scale INV
P2.14.1.8
Control Output
Filtering rime
0.000 32.000 s
0.000
1721
4.14.2
DIN ID control 1
Table 44.
DIN ID control parameters, G2.2.8
Code
Parameter
Min
Max
Unit
Default
Cust
ID
Description
P2.14.2.1
ID Control DIN
0.1
E.10
0.1
1570
Slot Board input No.
If 0.1 ID61 can be
controlled from FB
P2.14.2.2 Controlled
ID
0
10000 ID
0
1571
Select ID that is
controlled by digital input
P2.14.2.3
False value
-32000
32000
0
1572
Value when DI is low
P2.14.2.4
True value
-32000
32000
0
1573
Value when DI is high
4.14.3
DIN ID control 2
Table 45.
DIN ID control parameters, G2.2.8
Code
Parameter
Min
Max
Unit
Default
Cust
ID
Description
P2.14.3.1
ID Control DIN
0.1
E.10
0.1
1590
Slot Board input No.
If 0.1 ID61 can be
controlled from FB
P2.14.3.2 Controlled
ID
0 10000 ID
0
1575
Select ID that is
controlled by digital input
P2.14.3.3
False value
-32000
32000
0
1592
Value when DI is low
P2.14.3.4
True value
-32000
32000
0
1593
Value when DI is high