Parameter list
vacon · 53
24-hour support: +358 (0)201 212 575 • Email: [email protected]
4
4.12
Synchronisation to external grid
Table 41.
Code
Parameter
Min
Max
Unit
Default
ID
Description
P2.12.1 Synch.
Offset -3172 3171
0
1601
Used to compensate for
transformer angle offset.
(3172 equals 180 degrees
offset).
P2.12.2 Synch
Reference -3170 3170
0
1611
Gives synchronisation point
for synch error.
P2.12.3 Synch
Kp
0 32000
500
1612
P2.12.4 Synch
Ti
0
32000
0
1613
P2.12.5 Synch.
Hysteresis -3170 3170
50
1614
P2.12.6 Contactor
Delay
0
1000 ms
0
1624
In case no feedback from
shore contactor, this can be
used to simulate feedback
signal.
P2.12.7
Synch Stop Mode
0
1
0 / Stay Run
1618
When stop is selected, drive
will go to stop mode when
feedback from shore
contactor.
4.13
Synchronisation to shaft generator
Table 42.
Code
Parameter
Min
Max
Unit
Default
ID
Description
P2.13.1
SG Follower
Ramp Time
1.0 600.0 s
3.0 1527
P2.13.2
SG Grid Phase
Offset
-3200 3200
0
1586
P2.13.3 Synch
Gain
0 10.00
Hz
0.50
1778
P2.13.4
Phase Synch
Ramp Time
0.00 10.00 S
0.02 1777
P2.13.5
Max Synch Correct
0
3200
3000
1992
P2.13.6
Ramp Change
Hysteresis
0 3070
3000 1894