72
•
Operational Reference
Linea2 5GigE Series Camera
Example: Counter Start Source = OFF
Countermode = OFF
Counter is
IDLE
Counter
Overflow
CounterEnd Event Generated
Counter is
Active
CounterStartSource = OFF
Counter
Trigger Wait
Counter is incrementing
Countermode = Active
CounterResetSource = OFF
CounterResetSource = Event
Counter Reset CMD
Counter
Completed
CounterResetSource = CounterEnd
CounterStartSource = OFF
0
Figure 49: Example
–
Counter Start Source = OFF
•
The counter starts on the
counterReset Cmd
.
•
The counter continues unless a new
counterReset Cmd
is received, which restarts the counter
at 00.
•
When
Counter Reset Source = Event
or
CounterEnd
the counter is reset to 00 but does not
restart counting, until the next
CounterReset Cmd
.
Example: Counter Start Source = CounterEnd (itself)
Countermode = OFF
Counter is
IDLE
CounterEnd Event Generated
Counter is
Active
CounterStartSource =
CounterEnd (itself)
Counter
Trigger Wait
Counter is incrementing
Countermode = Active
Counter Reset CMD
Counter
Completed
CounterResetSource = CounterEnd
CounterStartSource = CounterEnd (itself)
0
Figure 50: Example
–
Counter Start Source = CounterEnd
•
Counter starts when
Counter Mode
is set to Active.
•
A
Counter Reset CMD
will reset the counter to 00 and continues counting.