Linea2 5GigE Series Camera
Operational Reference
•
77
Flat Field Correction Feature Descriptions
Display Name
Feature & Values
Description
Standard
& View
flatfieldCorrectionMode
Sets the mode for the Flat Field correction.
Beginner
DFNC
Off
Off Flat Field Correction is disabled.
Active
Active Flat Field Correction is enabled.
Calibration
Calibration When this mode is selected, the camera is
configured for flat field correction calibration. The
device may automatically adjust some of its
features when calibrate mode is enabled. The
features that are automatically adjusted are device
specific. The device will not restore these features
when the Flat Field Correction Mode feature is
changed from Calibrate mode to another mode.
Flat Field Correction Current
Active Set
flatfieldCorrectionCurrentActiveSet
Specifies the current set of Flat Field coefficients to
use.
Beginner
DFNC
Factory Flatfield
FactoryFlatfield Sets the factory Flat Field coefficient table as the
current Flat Field.
User Flatfield 1
UserFlatfield1 Sets User Flat Field 1 coefficient table as the
current Flat Field.
User Flatfield 2
UserFlatfield2 Sets User Flat Field 2 coefficient table as the
current Flat Field.
User Flatfield 3
UserFlatfield3 Sets User Flat Field 3 coefficient table as the
current Flat Field.
User Flatfield 4
UserFlatfield4 Sets User Flat Field 4 coefficient table as the
current Flat Field.
Flat Field Correction Type
flatfieldCorrectionType
Specifies the Flat Field correction type.
Guru
DFNC
Line-Based
LineBase Flat field correction is based on a single line of gain
and offset coefficients.
Flat Field Correction
Algorithm
flatfieldCorrectionAlgorithm
Specifies the Flat Field correction algorithm to use.
Guru
DFNC
Method 1
Method1 The following formula is used to calculate the flat
field corrected pixel: newPixelValue[x][y] =
(sensorPixelValue[x][y] - FFCOffset[x] [y]) *
FFCGain[x] [y]
Flat Field Calibration
Algorithm
flatfieldCorrectionCalibrationAlgorithm
Specifies the flatfield calibration algorithm to use.
Guru
DFNC
Peak
Peak Each pixel is gained up to the brightest.
Set Target
Target Each pixel is gained up to the value specified in the
flatfieldCalibrationTarget feature.
Flat Field Calibration Target
(in DN)
flatfieldCalibrationTarget
Sets the target pixel value for the gain (PRNU)
calibration.
Expert
DFNC
Flat Field Calibration Sample
Size
flatfieldCalibrationSampleSize
Set flat field calibration sample size (number of
lines to sum).
Guru
DFNC
2048
Lines_2048 2048
4096
Lines_4096 4096
Flat Field Calibration Row
Selector
flatfieldCalibrationColorSelector
Selects which row/color is calibrated.
Beginner
DFNC
All Rows
All
All rows calibrated.
Flat Field Calibration Offset
X
flatfieldCalibrationROIOffsetX
Sets the ROI Offset X.
Guru
DFNC
Flat Field Calibration Width
flatfieldCalibrationROIWidth
Sets the ROI Width.
Guru
DFNC
Calibrate FPN
flatfieldCalibrationFPN
Performs Fixed Pattern Noise (FPN) calibration by
reducing to zero dark pixel current using a pixel
offset.
Guru
DFNC