68
•
Operational Reference
Linea2 5GigE Series Camera
Display Name
Feature & Values
Description
Standard
& View
Counter Incremental
Source
counterIncrementalSource
Select the event source which increments the counter.
The Event Control section provides details and timing diagrams
for the supported events.
Expert
DFNC
Off
Off Counter is stopped.
Acquisition Start
AcquisitionStart Counts the number of Acquisition Start events.
Acquisition End
AcquisitionEnd Counts the number of Acquisition End events.
Exposure Start
ExposureStart Counts the number of Exposure Start events.
Exposure End
ExposureEnd Counts the number of Exposure End events.
Exposure Start (Blue)
ExposureStartBlue Counts the number of Exposure Start events.
Exposure Start (Red)
ExposureStartRed Counts the number of Exposure Start events.
Exposure Start
(Green)
ExposureStartGreen Counts the number of Exposure Start events.
Exposure Start (NIR)
ExposureStartNIR Counts the number of Exposure Start events.
Exposure End (Blue)
ExposureEndBlue Counts the number of Exposure End events.
Exposure End (Red)
ExposureEndRed Counts the number of Exposure End events.
Exposure End (Green)
ExposureEndGreen Counts the number of Exposure End events.
Exposure End (NIR)
ExposureEndNIR Counts the number of Exposure End events.
GPI Line 1
Line1 Counts the number of transitions on Line 1 (based on the
counterIncrementalLineActivation feature setting).
See Input Signals Electrical Specifications.
GPI Line 2
Line2 Counts the number of transitions on Line 2 (based on the
counterIncrementalLineActivation feature setting).
GPI Line 3
Line3 Counts the number of transitions on Line 3 (based on the
counterIncrementalLineActivation feature setting).
GPI Line 4
Line4 Counts the number of transitions on Line 4 (based on the
counterIncrementalLineActivation feature setting).
GPO Line 3
GPOLine3 Counts the number of transitions (based on the
counterIncrementalLineActivation feature setting) of GPO Line
3.
GPO Line 4
GPOLine4 Counts the number of transitions (based on the
counterIncrementalLineActivation feature setting) of GPO Line
4.
GPO Line 5
GPOLine5 Counts the number of transitions (based on the
counterIncrementalLineActivation feature setting) of GPO Line
5.
GPO Line 6
GPOLine6 Counts the number of transitions (based on the
counterIncrementalLineActivation feature setting) of GPO Line
6.
Rotary Encoder
RotaryEncoder1 Counter increments on the Rotary Encoder.
Frame Start
FrameStart Counts the number of Frame Start events.
Valid Frame(s)
Trigger
ValidFrameTrigger Counts the number of Valid Frame(s) Trigger events.
Rejected Frame(s)
Trigger
InvalidFrameTrigger Counts the number of Rejected Frames(s) Trigger events.
Valid Line Start
LineStart Counts the number of Line Start events.
Valid Line Trigger
ValidLineTrigger Counts the number of Valid Line events.
Rejected Line Trigger
InvalidLineTrigger Counts the number of Invalid Line events.
Internal Clock
InternalClock Counts the number of Internal Clock events.
Timer 1 End
Timer1End Counts the number of Timer End events.
Timer 2 End
Timer2End Counts the number of Timer End events.