Linea2 5GigE Series Camera
Operational Reference
•
95
Display Name
Feature & Values
Description
Standard
& View
Action Command
Source
actionCMDSource
Select the camera event that will generate an action
command on the network.
Guru
DFNC
Off
Off Action command is disabled.
ValidFrameTrigger
ValidFrameTrigger A Valid Frame Trigger event will generate an action
command.
InvalidFrameTrigger
InvalidFrameTrigger An Invalid Frame Trigger event will generate an action
command.
StartofFrame
StartofFrame A Start of Frame event will generate an action command.
StartofExposure
StartofExposure A Start of Exposure event will generate an action command.
EndofExposure
EndofExposure An End of Exposure event will generate an action command.
EndofTimer1
EndofTimer1 A TimerEnd1 event will generate an action command.
EndofCounter1
EndofCounter1 A CounterEnd1 event will generate an action command.
Input0
Input0 An Input Signal 0 event will generate an action command.
Input1
Input1 An Input Signal 1 event will generate an action command.
Action Command
Source Line Activation
actionCMDActivation
Specifies the activation mode to trigger an action command
from the selected line of the actionCMDSource feature.
Guru
DFNC
Falling Edge
FallingEdge Use the falling edge of the source signal.
Rising Edge
RisingEdge Use the rising edge of the source signal.
Action Schedule Delay
(in ns)
actionScheduleDelay
Delay to add to the current time when generating the
scheduled action command. A delay of 0 will generate an
immediate action command (not scheduled). A high enough
value must be chosen to allow for the generated action
command to propagate over the network before the
scheduled time expires.
Guru
DFNC
GigE Vision Action Command Reference
An Action Command is a single Broadcast packet sent from the Host Software application to all
cameras connected on the same network. How cameras act on an Action Command depends on its
designed feature support. Cameras receiving the Action Command broadcast may have one or
multiple functions acting on that received command.
Please refer to the GigE Vision® Specification
—
version 2.0 RC6, for configuration and usage
details. Contact Teledyne DALSA Support and request example code for Action Command usage.
Features Supporting Action Command
Feature Category
Feature
Enumeration
I/O Control
Trigger Selector
Single Line Trigger(Start)
Single Frame Trigger(Start)
MultiFrame Trigger(Start)
Frame Active
Frame Burst Active
Output Line Source
Pulse On: Action 1
Pulse On: Action 2
Counter and Timer Control
Counter Start Source
Action 1
Action 2
Timer Start Source
Action 1
Action 2
Event Control
Timestamp Reset Source
Action 2