70
•
Operational Reference
Linea2 5GigE Series Camera
Display Name
Feature & Values
Description
Standard
& View
Counter Duration
counterDuration
Sets the duration (or number of events) before the CounterEnd
event is generated.
Expert
DFNC
Counter Value
counterValue
Read the current value of the selected counter. (RO)
Expert
DFNC
Counter Value At
Reset
counterValueAtReset
Reads the value of the selected counter when it was reset by a
trigger or by an explicit Counter Reset command. (RO)
Expert
DFNC
Counter Reset
counterReset
Resets the selected counter to zero. The counter starts
immediately after the reset. To temporarily disable the counter,
set the Counter Event Source feature to Off. (WO)
Expert
DFNC
Timer Selector
timerSelector
Selects which timer to configure.
Expert
DFNC
Timer 1
Timer1 Select Timer 1 to configure.
Timer 2
Timer2 Select Timer 2 to configure.
Timer Mode
timerMode
Select the timer mode. The selected Timer is Active or Disabled.
When Disabled, the Timer can be configured.
Expert
DFNC
Off
Off The selected Timer is Disabled.
Active
Active The selected Timer is Enabled.
Timer Status
timerStatus
Returns the current state of the timer. (RO)
Expert
DFNC
Timer Idle
TimerIdle The timer is idle. The CounterStartSource feature is
set to off.
Timer Trigger Wait
TimerTriggerWait The timer is waiting for a start trigger.
Timer Active
TimerActive The timer is counting for the specified duration.
Timer Completed
TimerCompleted The timer reached the TimerDuration count.
Timer Start Source
timerStartSource
Select the trigger source to start the timer.
The Event Control section provides details and timing diagrams
for the supported events.
Expert
DFNC
TimerReset Cmd
Off Starts with the reception of the TimerReset Icommand.
Acquisition Start
AcquisitionStart Start Timer on Acquisition Start event.
Acquisition End
AcquisitionEnd Start Timer on Acquisition End event.
Exposure Start
ExposureStart Timer starts on the reception of the Exposure Start event.
Exposure End
ExposureEnd Timer starts on the reception of the Exposure End event.
Exposure Start (Blue)
ExposureStartBlue Timer starts on the reception of the Exposure Start event.
Exposure Start (Red)
ExposureStartRed Timer starts on the reception of the Exposure Start event.
Exposure Start
(Green)
ExposureStartGreen Timer starts on the reception of the Exposure Start event.
Exposure Start (NIR)
ExposureStartNIR Timer starts on the reception of the Exposure Start event.
Exposure End (Blue)
ExposureEndBlue Timer starts on the reception of the Exposure End event.
Exposure End (Red)
ExposureEndRed Timer starts on the reception of the Exposure End event.
Exposure End (Green)
ExposureEndGreen Timer starts on the reception of the Exposure End event.
Exposure End (NIR)
ExposureEndNIR Timer starts on the reception of the Exposure End event.
Action 1
Action1 Timer starts on the reception of Action 1 event.
Action 2
Action2 Timer starts on the reception of Action 2 event.
GPI Line 1
Line1 Timer starts on the rising edge of signal on GPI Line 1.
GPI Line 2
Line2 Timer starts on the rising edge of signal on GPI Line 2.
GPI Line 3
Line3 Timer starts on the rising edge of signal on GPI Line 3
GPI Line 4
Line4 Timer starts on the rising edge of signal on GPI Line 4
GPO Line 3
GPOLine3 Timer starts on the rising edge of signal on GPO Line 3.
GPO Line 4
GPOLine4 Timer starts on the rising edge of signal on GPO Line 4.
GPO Line 5
GPOLine5 Timer starts on the rising edge of signal on GPO Line 5.
GPO Line 6
GPOLine6 Timer starts on the rising edge of signal on GPO Line 6.
Rotary Encoder
RotaryEncoder1 Timer starts on the rotary encoder signal.