130
•
Technical Specifications
Linea2 5GigE Series Camera
Input Signals Electrical Specifications
External Inputs Block Diagrams
Balanced RS422 Receive Mode
Termination Enable
Receive Input
INPUT (+)
PIN 5
INPUT (-)
Signal Ground
External
Signal
Single-Ended Logic Receive Mode
3.3V, 5V, 12V, 24V
Termination Enable (not used)
Receive Input
INPUT (+)
PIN 5
INPUT (-)
not connected
Signal Ground
External
Signal
Programmable Input Threshold
Figure 83: External Inputs Block Diagram
External Input Overview
•
The input signals can be used as trigger acquisition event, counter or timestamp event, or
integration control.
•
The input signal can be improved by User programmable debounce time from 0 to 255 µs in
1 µs steps.
Caution:
It is important to correctly configure external inputs before connecting
external signals. Connecting higher voltage signals to inputs configured as RS422
may damage the inputs.