Linea2 5GigE Series Camera
Camera Performance and Features
•
49
Saving & Restoring Camera Setup Configurations
A user system may use multiple illuminations, resolutions and responsiveness configurations in
order to cover different imaging situations. The camera includes 4 user sets where camera setup
information can be saved and restored at power up or during operation.
Factory setting configuration i
s loaded during the camera’s first power
-up.
Active Settings for Current Operation
Active settings are those used while the camera is running. These settings are stored in the
camera’s
volatile
memory and will be lost if the camera resets or loses power during operation.
The settings active during the current operation can be saved and restored when the camera is
powered on using the User Set Save parameter. Once saved, the current settings become the
selected user set.
Camera Configuration Selection Dialog
CamExpert provides a dialog than combines the selection of the Camera Power-up Configuration
and the Load / Save Configuration from Linea2 5GigE memory.
Figure 41: CamExpert
–
Power-up Configuration Dialog
Camera Power-up Configuration
The
Camera Power-up Configuration
list displays the camera configuration to load during
power-up (see UserSetDefaultSelector feature). The user can choose
Factory Setting
or one of four
saved
User Sets
.
Load / Save Configuration
This list allows the user to change the camera configuration after power-up (see
UserSetSelector
feature). To reset the camera to the factory configuration, select
Factory Setting
and click
Load
. To
save a current camera configuration to non-volatile memory, select
User Set 1
,
2
,
3
or
4
and click
Save
(see UserSetSave feature). Select a saved user set and click
Load
to restore a saved
configuration. By default, the user sets are shipped with the same settings as the factory set.