66
•
Operational Reference
Linea2 5GigE Series Camera
Counter and Timer Control Category
The Linea2 5GigE Counter and Timer Control category groups parameters used to configure
acquisition counters, timers and signal edge detection.
Figure 47: CamExpert
–
Counter and Timer Control Category
Counter and Timer Control Feature Descriptions
Display Name
Feature & Values
Description
Standard
& View
Counter Selector
counterSelector
Selects the counter to configure.
Expert
DFNC
Counter 1
Counter1 Select counter 1.
Counter 2
Counter2 Select counter 2.
Counter Mode
counterMode
Selects the counter mode. The selected Counter is either Active
or Disabled. When Disabled, the Counter can be configured.
Expert
DFNC
Off
Off The selected Counter is disabled.
Active
Active The selected Counter is enabled.
Counter Status
counterStatus
Returns the current state of the counter. (RO)
Expert
DFNC
Counter Idle
CounterIdle The counter is idle. The CounterStartSource feature is set to off.
Counter Trigger Wait
CounterTriggerWait The counter is waiting for a start trigger.
Counter Active
CounterActive The counter is counting for the specified duration.
Counter Completed
CounterCompleted The counter reached the CounterDuration count.
Counter Overflow
CounterOverflow The counter reached its maximum possible count.