62
•
Operational Reference
Linea2 5GigE Series Camera
Display Name
Feature & Values
Description
Standard
& View
Line Selector
LineSelector
Selects the physical line (or pin) of the external device
connector to configure.
Beginner
Line 1
Line1 Index of the physical line and associated I/O control block
to use. Pin 1 and Pin 2 is the RS-422 Input Port 1+, 1-,
respectively.
Line 2
Line2 Index of the physical line and associated I/O control block
to use. Pin 3 and Pin 4 is the RS-422 Input Port 2+ and
2-, respectively.
Line 3
Line3 Index of the physical line and associated I/O control block
to use. Pin 6 and Pin 7 is the Port 3+ and 3-, respectively.
Line 4
Line4 Index of the physical line and associated I/O control block
to use. Pin 8 and Pin 9 is the Port 4+ and 4-, respectively.
Line 5
Line5 Index of the physical line and associated I/O control block
to use. Pin 11 and Pin 12 is Output Port 5+ and 5-,
respectively.
Line 6
Line6 Index of the physical line and associated I/O control block
to use. Pin 13 and Pin 14 is the Output 6+ and 6-,
respectively.
Line Format
LineFormat
Specify the current electrical format of the selected
physical input or output.
Expert
RS422
RS422 The line accepts or sends RS422 level signals.
Single Ended
SingleEnded The line accepts or sends SingleEnded signals.
DFNC
Open Collector
OpenCollector The line is output as an open collector.
DFNC
Line Mode
LineMode
Reports if the physical Line is an Input or Output signal.
(RO)
Expert
Input
Input The line is an input line.
Output
Output The line is an output line.
Line Status
LineStatus
Returns the current status of the selected input or output
line. (RO)
Expert
False/True
Line Inverter
LineInverter
Controls the inversion of the signal of the selected input
or output Line.
Beginner
False/True
Input Line Detection Level
lineDetectionLevel
Specifies the voltage threshold required to recognize a
signal transition on an input line.
Expert
DFNC
Threshold for 3.3V
Threshold_for_3V3 A signal below 1.45V will be detected as a Logical LOW
and a signal greater than 1.85V will be detected as a
Logical HIGH on the selected input line.
Threshold for 5V
Threshold_for_5V A signal below 2.3V will be detected as a Logical LOW and
a signal greater than 2.7V will be detected as a Logical
HIGH on the selected input line.
Threshold for 12V
Threshold_for_12V A signal below 5.8V will be detected as a Logical LOW and
a signal greater than 6.2V will be detected as a Logical
HIGH on the selected input line.
Threshold for 24V
Threshold_for_24V A signal below 10.0V will be detected as a Logical LOW
and a signal greater than 11V will be detected as a Logical
HIGH on the selected input line.
Input Line Debouncing
Period (in us)
lineDebouncingPeriod
Specifies the minimum delay before an input line voltage
transition is recognized as a signal transition.
Beginner
DFNC
Line Electrical Termination
lineElectricalTermination
Controls if the electrical termination of Input Line is
enabled or disabled.
Expert
DFNC
Disabled
Disabled Disabled electrical line termination for the selected line.
Enabled
Enabled Enabled electrical line termination for the selected line.