AC Repair and Adjustment Procedures
FRP 19: Blower Controller Bypass Switch (SW3) Replacement
HMM-168-A
Cray Research/Silicon Graphics Proprietary
123
Figure 59. Removing the Blower Controller Bypass Switch
6.
Use your fingers to depress the bottom flange on the switch as you push
the bottom of switch through the cutout in the WACS box.
7.
Record the locations of the wires that connect to the switch. Do not
disconnect the wires yet.
8.
Mark the switch to identify it as defective.
Switch Installation
1.
Carefully move the wires from the defective switch to the replacement
switch, one wire at a time. Then set the defective switch aside.
2.
After you install the wires on the replacement switch, push the switch
through the cutout in the WACS box until it locks in place.
3.
Replace the panel that covers the blower controller (SCR1). Four #2
Phillips screws hold the panel in place.
4.
Return the cabinet to operation, and check the switch function.
5.
Close the WACS panel.
6.
Close the front cabinet door.
WACS
Panel
Switch
View is from left side of cabinet
Top Flange
Step 5