FRP 5: Module Replacement
AC Repair and Adjustment Procedures
38
Cray Research/Silicon Graphics Proprietary
HMM-168-A
5.
Replace the module panel.
6.
Turn the power supply circuit breaker on.
7.
Take all necessary steps to restore the module to a functional state. (For
example, reconfigure the torus configuration and press the Restart button.)
NOTE:
If any PEs fail to deadstart after service, run
bscan
; then run
scan clear
.
8.
Check the WACS display and the power supply and module power
indicator LEDs.
9.
Close the front and rear cabinet doors.
Packing a Module in a Shipping Container
1.
Ensure that the defective module contains plastic cams (shuttle connector
locks – P/N 12919100) and that all exposed daughter-card pin connectors
are covered by pin protectors (P/N 15145700).
shows a pin
protector.
Figure 13. Pin Protector
CAUTION
Observe all ESD precautions. Failure to
do so could result in additional damage
to the equipment.
Guide
Pin
Pin
Protector
Retaining
Screw