FRP 14: Module-to-WACS Cable Replacement
AC Repair and Adjustment Procedures
108
Cray Research/Silicon Graphics Proprietary
HMM-168-A
Figure 52. Wire Insertion with Wire Rod
1.
2.
3.
4.
1. Thread the wire rod through the appropriate pin
slot in the connector block, as shown. Ensure that
the plastic tip on the wire rod is at the wire-insertion
end of the connector block, and ensure that the
slanted portion of the cavity in the plastic tip faces
the outside of the connector block.
Then, insert the 2-pin connector into the cavity, as
shown at left. The cavity pinches the pins together
as you insert the connector.
2, 3, & 4. Pull the rod through the connector block
to insert the 2-pin connector. If necessary, seat the
connector with your fingertip.