AC Repair and Adjustment Procedures
FRP 7: Power Supply Rail Replacement
HMM-168-A
Cray Research/Silicon Graphics Proprietary
51
Rail Installation
1.
If necessary, use a #3 Phillips screwdriver to remove the slot cover from
the slot. (Necessary during an upgrade.)
2. Check the new rail for damper function, obvious foam defects, etc.
3. Position the new rail in the module box (card cage). Place the module end
of the rail against the brace (crossbar) in the module box.
4.
Secure the rail with the shoulder screws:
a. Insert the screws that you removed. Tighten all screws finger tight.
b. Ensure that the rail is aligned with the module. (You may want to
insert the power supply to ensure alignment.)
c. Tighten the screws securely.
5.
Carefully replace the power supplies. (Refer to
.) Correct any
alignment problems.
6.
Return the system to operation, and close the front cabinet door.