AC Repair and Adjustment Procedures
FRP 2: Removing the Cabinet Side Panel
HMM-168-A
Cray Research/Silicon Graphics Proprietary
17
6.
Remove the bottom wire-duct covers and the top rear wire-duct covers to
expose the retaining studs that hold the panel to the frame. Eight #2 (M4)
Phillips screws secure each panel. (Refer to
.)
NOTE:
You may not be able to remove the bottom front wire-duct
covers unless you remove the power box cover or the input
power access plate. However, if you loosen the bottom center
screw on the wire-duct cover, you may be able to rotate the
wire-duct cover out of the way.
7.
If you plan to remove the left panel, disconnect the connector for the
Cabinet Power switch (SW2). The connection is located near the top stud
(retaining bolt) on the power-supply end of the left panel.
Figure 4. Side Panel Bolt and Wire Duct Locations
8.
Use a 10-mm socket to remove the nuts and washers from the bottom
retaining studs. (Be careful not to drop any nuts or washers into the wire
channels.)
Holes for Bottom
Retaining Bolts
Holes for Top
Retaining Bolts
Wire
Duct
Covers