AC Repair and Adjustment Procedures
FRP 4: Auxiliary Clock Power Supply Replacement
HMM-168-A
Cray Research/Silicon Graphics Proprietary
29
FRP 4: Auxiliary Clock Power Supply Replacement
Use this procedure to replace the auxiliary power supply that supports the clock
distribution amplifier. This procedure describes the steps for replacing the first
version of the auxiliary clock power supply. If your system’s power supply differs
from the one documented here, modify the procedure as needed.
Part Number
•
15258000 (power supply assembly, dual output, clock)
Tools Required
•
Short-handled #2 Phillips screwdriver
•
Small flatblade screwdriver
Power Supply Removal
1.
Open the front cabinet door.
2.
Open the cabinet’s main disconnect circuit breaker (CB1) and unplug the
cabinet.
You may also open, lock, and tag the customer’s wall breaker(s).
3.
Open the secondary circuit breaker (CB10) that controls power to the
auxiliary clock power supply.
4.
Disconnect the power cord from the auxiliary power supply.
WARNING
Failure to take adequate power-removal
precautions and avoid live power
components could result in severe
shock and burns.