FRP 35: Contactor (CT1) Replacement
AC Repair and Adjustment Procedures
174
Cray Research/Silicon Graphics Proprietary
HMM-168-A
b. Pull the cover straight up, then remove it from the cabinet. Be careful
not to damage the inlet air thermistors or the EMI gasket on the bottom
of the cover.
5.
Record the locations of the 4 wires that connect to the front of the
contactor, and remove the wires with a medium flatblade screwdriver.
6.
Remove the two 7-mm nuts that hold the contactor to studs on the floor of
the power box.
7.
Pull the contactor forward so that you can access the wires on the back of
the contactor, then record the locations of the wires that connect to the
back of the contactor.
8.
Remove the wires with a medium flatblade screwdriver.
Figure 78. Contactor Location
Cabinet Front
(power supply insertion side)
Cabinet Rear
(module insertion side)
Contactor