6.
If the wire that you are removing passes from one cabinet to another, open
the cable ducts where the wire passes between cabinets. Refer to
a. Use a #1 Phillips screwdriver to loosen the five Phillips screws that
secure each air seal assembly on the cable ducts.
b. Lift (or lower, in the case of the Y-side wiremat) the air seal assemblies
to provide room for the wire. The air seal assemblies contain slots that
move up and down on the Phillips screws.
c. Secure the air seal assemblies in the open position by tightening the
Phillips screws on the assemblies.
Figure 28. Intercabinet Cable Ducts (as viewed from the inside of the cabinet)
Closed Cable Duct
Open Duct
Foam
Strips
Duct Seal
Duct Seal
Retaining Screws