AC Repair and Adjustment Procedures
FRP 20: Cabinet Power Switch (SW2) Replacement
HMM-168-A
Cray Research/Silicon Graphics Proprietary
125
5.
Use the 6-mm wrench to remove the switch box that encloses the Cabinet
Power switch.
6.
Record the locations of the wires that connect to the switch, then carefully
remove the wires.
7.
Squeeze the side flanges of the switch body together as you push the
switch out the front of the door.
Switch Installation
1.
Push the switch through the opening in the switch box until the flanges
lock the switch in place.
2.
Connect the switch wires.
3.
Replace the switch box.
4.
Apply power to the cabinet and check the switch function.
5.
Replace the aesthetic panel and the EMI filter.
6.
Close the front door.
7.
Return the cabinet to operation.
CAUTION
The edges of the fiberglass door panel are fragile. Be careful not to
drop the door. When you set the door aside, ensure that the weight
is supported by portions of the fiberglass that can bear the weight.