FRP 18: WACS Panel Switch (SW6, SW7, SW8) Replacement
AC Repair and Adjustment Procedures
120
Cray Research/Silicon Graphics Proprietary
HMM-168-A
FRP 18: WACS Panel Switch (SW6, SW7, SW8) Replacement
Use the following procedure when you replace the Restart, Remote Restart
Enable, or Power Supply Margin switch.
Part Number
•
57186400 (switch, PB gold contacts -- Restart)
•
57186500 (switch, rocker green LED -- Remote Restart Enable)
•
57186700 (switch, rocker green LED -- Power Supply Margin)
Tools Required
•
Needlenose pliers (optional for wire removal)
Switch Removal
1.
Open the front cabinet door.
2.
Open the cabinet’s main disconnect circuit breaker (CB1) and unplug the
cabinet. Place a lockout device over the cabinet’s plug and lock/tag it.
You may also open, lock, and tag the customer’s wall breaker(s).
3.
Open the WACS panel.
4.
Record the locations of the wires that connect to the switch.
NOTE:
You will leave the wires on the switch until you release it from
the WACS panel. You will then transfer the wires to the
replacement switch.
WARNING
Ensure that the electrical plug for the
equipment that you service is
unplugged, locked, and tagged. Failure
to do so could result in severe shock
and burns.