FRP 2: Removing the Cabinet Side Panel
AC Repair and Adjustment Procedures
16
Cray Research/Silicon Graphics Proprietary
HMM-168-A
FRP 2
:
Removing the Cabinet Side Panel
For system upgrades and other procedures, you may need to remove at least one
side panel to gain access to the logic cables, etc. Four bolts hold each panel to
the frame – one bolt in each corner of the frame.
Tools Required
•
Small flatblade screwdriver
•
#2 (M4) Phillips screwdriver
•
Socket wrench with 10-mm socket
Side Panel Removal Procedure
NOTE:
This procedure requires two people.
1.
Open the front cabinet door.
2.
Open the cabinet’s main disconnect circuit breaker (CB1) and unplug the
cabinet. Place a lockout device over the cabinet’s plug and lock/tag it.
You may also open, lock, and tag the customer’s wall breaker(s).
3.
Open the rear cabinet door.
4.
Disconnect the cable from the clock switch board. Two flathead screws
secure the cable to the board.
5.
Remove the blower exhaust shield. Six #2 (M4) Phillips screws secure the
shield to the cabinet.
WARNING
Ensure that the electrical plug for the
equipment that you service is
unplugged, locked, and tagged. Failure
to do so could result in severe shock
and burns.