AC Repair and Adjustment Procedures
FRP 10: Logic Cable Replacement
HMM-168-A
Cray Research/Silicon Graphics Proprietary
67
b. Lift (or lower, in the case of the Y-side wiremat) the air seal assemblies
to provide room for the cable. The air seal assemblies contain slots that
move up and down on the Phillips screws.
c. Secure the air seal assemblies in the open position by tightening the
Phillips screws on the assembly.
10. Remove the module where the defective cable is mounted and remove
additional modules to provide clear access to the rail. Refer to
FRP 5
. Put
the modules in a protected location that is ESD safe.
11. If you are removing a Z-side (top) cable, place pink foam in the bottom of
the card cage to catch any screws that you might drop in subsequent steps.
12. Remove the 7 nylon screws that hold the plastic slot guide to the rail.
Refer to
. Use a medium flatblade screwdriver that fits the
screws snugly. Be careful not to damage or lose any screws. Set the
screws in a secure location.
13. Slide the slot guide out of the rail horizontally.
shows the slot
guide.
14. Remove the defective cable:
a. Return to the wiremat area, and carefully remove the foam from the
connector slot where the defective cable enters the rail; tweezers may
be helpful. (Each connector slot contains an oval piece of foam, which
tears easily. Refer to
b. Remove any tie straps that secure the defective cable.
c. Disconnect the cable by disconnecting both ribbon cable connections
in the wiremat. Refer to
d. Use the 0.05-in. hex wrench to remove the 2 hex screws (and brass
spacer if applicable) that secure the connector to the rail. Refer to
. Be careful not to lose any screws; set the screws in a secure
location.
The screws are P/N 13033501. The brass spacer is P/N 12755600.
e. Slide the connector toward the air damper until it clears the other
connectors, then pull the connector out of the rail and into the wiremat.
f. Remove the cable from the wiremat.