FRP 38: Blower Assembly Replacement
AC Repair and Adjustment Procedures
182
Cray Research/Silicon Graphics Proprietary
HMM-168-A
FRP 38: Blower Assembly Replacement
The blower is heavy and at an awkward position. Two people may be required
to remove and install it safely. Have a second person available when you remove
and install the blower.
Part Number
•
57178900 (blower assy, 18 inch)
Tools Required
•
Small flatblade screwdriver
•
4-mm hex (allen) wrench with hex driver and extension
•
Flashlight
Blower Removal
1.
Open the front cabinet door.
2.
Open the cabinet’s main disconnect circuit breaker (CB1) and unplug the
cabinet. Place a lockout device over the cabinet’s plug and lock/tag it.
You may also open, lock, and tag the customer’s wall breaker(s).
3.
Open the rear cabinet door.
4.
Use a small flatblade screwdriver to disconnect the clock cable connector
from the clock switch board.
WARNING
Ensure that the electrical plug for the
equipment that you service is
unplugged, locked, and tagged. Failure
to do so could result in severe shock
and burns.