FRP 13: Boundary Scan Cable/Wire Replacement
AC Repair and Adjustment Procedures
88
Cray Research/Silicon Graphics Proprietary
HMM-168-A
Wire Removal
1.
Open the front cabinet door.
2.
Open the cabinet’s main disconnect circuit breaker (CB1) and unplug the
cabinet. Place a lockout device over the cabinet’s plug and lock/tag it.
You may also open, lock, and tag the customer’s wall breaker(s).
3.
Open the rear cabinet door.
4.
Use a small flatblade screwdriver to disconnect the cable from the clock
switch board.
5.
Use a #2 Phillips screwdriver to remove the blower exhaust shield. Six #2
Phillips screws hold the shield in place.
6.
Loosen the eight 1/4-turn captive screws that secure the module panel,
then pull the module panel out of the cabinet at an angle.
7.
Remove the upper plenum panel to provide access to the wire assembly.
Six #1 Phillips screws hold the panel in place.
CAUTION
Observe all ESD precautions. Failure to
do so could result in damage to the
equipment.
WARNING
Ensure that the electrical plug for the
equipment that you service is
unplugged, locked, and tagged. Failure
to do so could result in severe shock
and burns.