AC Repair and Adjustment Procedures
FRP 7: Power Supply Rail Replacement
HMM-168-A
Cray Research/Silicon Graphics Proprietary
49
FRP 7: Power Supply Rail Replacement
Removal and installation of top rails may require two people.
Part Number
One of the following parts:
•
57252400 (power supply rail assembly, bottom)
•
57252500 (power supply rail assembly, top)
Tools Required
•
4-mm hex (allen) wrench with hex driver
•
#3 Phillips screwdriver
Rail Removal
1.
Open the front cabinet door.
2.
Open the cabinet’s main disconnect circuit breaker (CB1) and unplug the
cabinet. Place a lockout device over the cabinet’s plug and lock/tag it.
You may also open, lock, and tag the customer’s wall breaker(s).
3.
Remove the power supply from the defective rail, and remove the
adjacent power supplies to provide access. Refer to
4.
Use the hex wrench to remove the 4 shoulder screws (2 at each end of the
rail), then remove the rail from the cabinet. Refer to
.
WARNING
Ensure that the electrical plug for the
equipment that you service is
unplugged, locked, and tagged. Failure
to do so could result in severe shock
and burns.