FRP 14: Module-to-WACS Cable Replacement
AC Repair and Adjustment Procedures
104
Cray Research/Silicon Graphics Proprietary
HMM-168-A
Figure 49. Connector Removal with Mechanical Pencil
16. If you are replacing a PEM-to-WACS cable, use the following procedure
to remove the cable connector from the control bulkhead above the
modules:
a. Use a small flatblade screwdriver to remove the 2 screws that secure
the associated WACS harness connector to the control bulkhead. Then
remove the WACS harness connector.
b. Use a 5-mm hex (allen) wrench to loosen the two jackpost screws that
secure the PEM-to-WACS cable to the control bulkhead. Then remove
the PEM-to-WACS cable from the cabinet.
17. If you are replacing a clock-to-WACS cable, use the following procedure
to remove the cable connector from the panel behind the I/O bulkhead.
a. Swing the I/O bulkhead toward you to expose the panel behind it.
Locate the clock-to-WACS cable connection. Note that you must
disconnect the cable from the other side of the panel as described in
the following steps.
Slip the hollow
point of the
pencil over the
outer pin.
Gently angle the
pencil so that the
outer pin bends
toward the inner pin.
This releases the pin
lock.
Push the 2-pin
connector out
of the rail
connector.
Latch
Pencil
Rail
Connector
Step 15