Function 56h, Service 00 –
Gas Gauge
Input:
ah = 56h
al = 00h
Returns:
Carry Flag clear if successful
ah= bit fields
bits 2, 1, 0 = 00h High
= 01h Low
= 02h Critical
= 03h Unknown
bits 4, 3
= 00h AC off-line
= 01h AC on-line
= 03h Unknown
al = Remaining Battery Pack capacity (0 to 100),
-1 if charging
Carry Flag set on error
Notes:
This function retrieves information about the current
power status.
Function 57h, Service 00 –
BIOS Version
Input:
ah = 57h
al = 00h
Returns:
Carry Flag clear if successful
ah= major version number
al = minor version number
Carry Flag set on error
Notes:
This function returns the Apex PDT BIOS version in
decimal form. For example, values of ah = 01d and al =
34d are returned for BIOS version v1.34.